Airway_bronchiole_alveolus
This model represents an inertial flow in a rigid airway, compliant bronchiole, compliant bronchiolus and a compliant alveolus.
Model number: 0072
| Run Model:  |     Help running a JSim model. |
Description
This model represents a rigid airway, compliant bronchiole, compliant bronchiolus and a compliant alveolus. A single resistor (R11) represents the resitance offered by the airway wall to the airflow. The compliance and the resitance of the bronchiole are represented by the resistor (R21 and R22) and the capacitor (Com21). Likewise the compliance and the resistance offered by the respiratory bronchiole or the bronchiolus are represented by the resistor (R31 and R32) and a capacitor (Com31). The alveolar sac compliance is repsented by a capcitor (Com4). The alveolar sac changes its volume as a function of inlet flow or pressure. The resistance offered by the alveolus is represented by R41.
Equations
P12 - P21 = Finlet * R21
P21 - P22 = F22 * R22
P21 = (V21-V21_0)/Com21
P22 - P31 = F22 * R31
P31 = (V31-V31_0)/Com31
P31 - P32 = F32 * R32
P32 - P41 = F32 * R41
P41 = (V41-V41_0)/Com41
d(Finlet)/dt = (Pinlet - P12 - (Finlet * R11))/L11
d(V21)/dt = F21
d(V31)/dt = F31
d(V41)/dt = F32
F21 = Finlet - F22
F31 = F22 - F32
Where: P is pressure, F is flow of “incompressible” air, R is resistance,
Com is capacitance, and V is the volume.
Download JSim model project file
References
K. R. Lutchen and G. M. Saidel, "Estimation of mechanical parameters in multicompartment models applied to normal and obstructed lungs during tidal breathing," IEEE Trans. Biomed. Eng., vol. BME-33, no. 9, pp. 878-887, Sept. 1986. Biomechanics by Y.C. Fung (Text Book)
Related Models
- Rigid airflow through bronchiloe to alveolus
- Rigid bifurcating bronchiole with two alveoli.
- Rigid bronchiole with compliant alveolus.
- Compliant bifurcating bronchiole
- Compliant bifurcating bronchiole with compliant alveoli
- Compliant bronchiole with compliant alveolus.
- Bifurcating compliant airway.
Key Terms
Model Feedback
We welcome comments and feedback for this model. Please use the button below to send comments:
Model History
Get Model history in CVS.Acknowledgements
Please cite www.physiome.org in any publication for which this software is used and send one reprint to the address given below:
The National Simulation Resource, Director J. B. Bassingthwaighte, Department of Bioengineering, University of Washington, Seattle WA 98195-5061.
[This page was last modified 08Feb10, 10:50 am.]
Model development and archiving support at physiome.org provided by the following grants: NIH/NIBIB BE08407 Software Integration, JSim and SBW 6/1/09-5/31/13; NIH/NHLBI T15 HL88516-01 Modeling for Heart, Lung and Blood: From Cell to Organ, 4/1/07-3/31/11; NSF BES-0506477 Adaptive Multi-Scale Model Simulation, 8/15/05-7/31/08; NIH/NHLBI R01 HL073598 Core 3: 3D Imaging and Computer Modeling of the Respiratory Tract, 9/1/04-8/31/09; as well as prior support from NIH/NCRR P41 RR01243 Simulation Resource in Circulatory Mass Transport and Exchange, 12/1/1980-11/30/01 and NIH/NIBIB R01 EB001973 JSim: A Simulation Analysis Platform, 3/1/02-2/28/07.