This page will look better in a graphical browser that supports web standards, but is accessible to any browser or internet device.

Served by Samwise.

Circ_with_Baroreceptors

A closed loop cardiopulmonary model composed of a four-chamber varying-elastance heart, a pericardium, a systemic circulation, a pulmonary circulation, a coronary circulation, and baroreceptors.

Model number: 0095

Run Model: 
    Help running a JSim model.
Java runtime required. (JSim model may take 10-20 seconds to load.)
MacOS: Adjust "System Preferences" -> "Security & Privacy" to allow Java JSim jnlp app to execute.
More info here.

Description

 The model simulates physiological features such as the arterial blood pressure waveform,
 end-diastolic left ventricular volume, and coronary capillary flow.

 This model is a reduced form of the Highly-integrated_human_with_interventions model. 
 The code for simulation of interventions and injuries (aka Physiological Changes), 
 peripheral chemoreceptors, blood gas handling, gas exchange, and airway mechanics has 
 been removed from the parent model to create the present system.

 The JSim project file allows the user to simulate certain interventions by changing 
 model parameters in the “Inputs” page. For example, the parameter for pulmonary valve 
 resistance (Rpuv) can be increased to simulate pulmonary valve stenosis. 

 This model is a reduced form of the Highly-integrated_human_with_interventions model, 
 which has been partially validated. The code for simulation of interventions and 
 injuries (aka Physiological Changes), peripheral chemoreceptors, blood gas handling, 
 gas exchange and airway mechanics has been removed from the parent model to create the 
 present system. 	

Equations

The equations for this model may be viewed by running the JSim model applet and clicking on the Source tab at the bottom left of JSim's Run Time graphical user interface. The equations are written in JSim's Mathematical Modeling Language (MML). See the Introduction to MML and the MML Reference Manual. Additional documentation for MML can be found by using the search option at the Physiome home page.

Download JSim model project file

References

 Brandenburg, Robert O. Cardiology: fundamentals and practice.
 Yearbook medical publishers, 1987. p. 49.

 Chung DC, Niranjan SC, Clark Jr. JW, Bidani A, Johnston WE,
 Zwischenberger JB, Traber DL. A dynamic model of ventricular
 interaction and pericardial influence.  Am J Phsiol Heart 
 Circ Physiol. 272: H2942-H2962, 1997.

 Golden JF, Clark JW, Stevens PM. Mathematical Modeling of 
 Pulmonary Airway Dynamics.  IEEE Transactions on Biomedical 
 Engineering. 20(6): 397-404, 1973.
 
 Heldt T, Shim EB, Kamm RD, Mark RG. Computational modeling of
 cardiovascular response to orthostatic stress.  Journal of 
 Applied Physiology. 92: 1239-1254, 2002.

 Kezdi P, and Geller E. Transfer characteristics of the
 carotid sinus pressure control system. In: Baroreceptors and
 Hypertension, Kezdi, P. (ed.) Pergamon, Dayton, OH, 1967,
 pp. 31-40.

 Lu K, Clark JW, Ghorbel FH, Ware DL, Bidani A.
 A human cardiopulmonary system model applied to the analysis
 of the Valsalva maneuver.  Am J Physiol Heart Circ Physiol.
 281: H2661-H2679, 2001. 

 Rideout VC. Mathematical computer modeling of physiological
 systems. Englewood Cliffs, NJ: Prentice Hall, 1991, 261 pp.

 Sun Y, Beshara M, Lucariello RJ, Chiaramida SA.  A 
 comprehensive model for right-left heart interaction under the
 influence of pericardium and baroreflex.  Am J Physiol Heart
 Circ Physiol. 272: H1499-H1515, 1997.

 Zinemanas D, Beyar R, Sideman S.  Relating mechanics, blood
 flow and mass transport in the cardiac muscle.  Int. J. Heat 
 Mass Transfer.  37(suppl. 1) 191-205, 1994.

Related Models

Models used by this model Related models

Key Terms

cardiovascular, pericardium, heart, systemic circulation, pulmonary circulation, coronary circulation, lumped parameter, baroreceptor, integrated physiology, integrative

Model Feedback

We welcome comments and feedback for this model. Please use the button below to send comments:

Model History

Get Model history in CVS.

Posted by: Name

Acknowledgements

Please cite www.physiome.org in any publication for which this software is used and send an email with the citation and, if possible, a PDF file of the paper to: staff@physiome.org.
Or send a copy to:
The National Simulation Resource, Director J. B. Bassingthwaighte, Department of Bioengineering, University of Washington, Seattle WA 98195-5061.

[This page was last modified 14Mar18, 3:17 pm.]

Model development and archiving support at physiome.org provided by the following grants: NIH U01HL122199 Analyzing the Cardiac Power Grid, 09/15/2015 - 05/31/2020, NIH/NIBIB BE08407 Software Integration, JSim and SBW 6/1/09-5/31/13; NIH/NHLBI T15 HL88516-01 Modeling for Heart, Lung and Blood: From Cell to Organ, 4/1/07-3/31/11; NSF BES-0506477 Adaptive Multi-Scale Model Simulation, 8/15/05-7/31/08; NIH/NHLBI R01 HL073598 Core 3: 3D Imaging and Computer Modeling of the Respiratory Tract, 9/1/04-8/31/09; as well as prior support from NIH/NCRR P41 RR01243 Simulation Resource in Circulatory Mass Transport and Exchange, 12/1/1980-11/30/01 and NIH/NIBIB R01 EB001973 JSim: A Simulation Analysis Platform, 3/1/02-2/28/07.